Mastercard: RRP grace periods and new Kernel 2 tests from January 2027
Mastercard's November 2026 Contactless Reader Vendor Approval Communiqué changes how Kernel 2 relay resistance is tested:
- DF8306: RRP accuracy tests can compute the Terminal Transmission Time from the Measured RRP Processing Time (DF8306) instead of the Time Taken, with immediate effect. The January test environment makes Time Taken optional.
- Grace periods: the Minimum and Maximum Relay Resistance Grace Periods should each be at least 2 ms, and their sum must not exceed 7 ms. Using the full 7 ms is recommended; below 6 ms in total, vendors may be asked for a justification or extra tests.
- Calibration: an RRP Calibration document helps vendors and laboratories set these values for a given terminal.
January 2027 test release (Contactless Reader V4.1): Mastercard adds a few new C-2 functional tests. These are not specification or requirement changes. The main changes are to:
- Latest ERRD response data: ensure the kernel always uses the latest ERRD response data when values change between responses. For example, if a card returns different values for the Max Time For Processing RRP APDU in its responses, the kernel must use the value from the second ERRD (if any) to decide whether to send a third ERRD.
- Unpredictable Number: enhance the test confirming that the Unpredictable Number cannot be predicted.
- Read-record parsing: relax the read-record parsing tests; the kernel could abort after the last record if an earlier record failed to parse.
Already approved products: kernels and PCD derivatives that already have a Letter of Approval must run the two new tests (RRP and Unpredictable Number) once, in addition to their Module Integration Tests, formerly called regression tests. A product that fails either test gets no Letter of Approval, including for renewal and derivative submissions.
See the Kernel 2 relay resistance guide in Guidance for how this maps to Book C-2.
Source: Mastercard Contactless Reader Vendor Approval Communiqué, November 2026 (sent to vendors and laboratories)